1.
Curr Oncol ; 30(8): 7740-7752, 2023 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-37623042

RESUMO

This study provided normal tissue complication probability (NTCP) calculations from photon radiotherapy techniques in eleven patients with thymoma. Five plans were created for each participant using three-dimensional conformal radiotherapy (3D-CRT), five-field intensity modulated radiotherapy (5F-IMRT), seven-field IMRT (7F-IMRT), and volumetric modulated arc therapy with full arcs (FA-VMAT) and partial arcs (PA-VMAT). The target coverage, homogeneity index and conformation number for the planning target volume (PTV) and dosimetric parameters for the organs-at-risk (OARs) were taken from the fifty-five generated plans. The patient-specific NTCP of the lungs, heart and esophagus was calculated with an in-house software tool using differential dose-volume histograms and the equivalent uniform dose model. The PTV dose metrics from 3D-CRT were inferior to those from IMRT and VMAT plans. The dose constraints for the OARs were met in all treatment plans. The NTCP range of the lungs, heart and esophagus was 0.34-0.49%, 0.03-0.06% and 0.08-0.10%, respectively. The NTCPs of the heart for the incidence of peridarditis from IMRT and VMAT were significantly smaller than those from conformal treatment (p < 0.05). The 7F-IMRT was significantly superior to FA-VMAT in reducing the NTCP of the lungs and the risk of pneumonitis (p = 0.001). Similar superiority of 5F-IMRT over PA-VMAT for lung protection was found (p = 0.009). The presented results may be employed in the selection of the appropriate irradiation technique for restricting the complications in the adjacent OARs.


Assuntos
Radioterapia , Timoma , Timoma/radioterapia , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Radioterapia/instrumentação , Radioterapia/métodos , Estudos Retrospectivos
2.
Radiat Prot Dosimetry ; 199(13): 1357-1366, 2023 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-37385263

RESUMO

This work aimed to develop and validate software that calculates the shielding thickness required for a radiotherapy room with a linear accelerator utilising geometric and dosimetric data. The software "Radiotherapy Infrastructure Shielding Calculations" (RISC) was developed using MATLAB programming. It does not require the installation of the MATLAB platform, and the user only needs to download and install the application, which displays a graphical user interface (GUI). The GUI includes empty cells to insert numerical values for several parameters to calculate the proper shielding thickness. The GUI comprises two main interfaces, one for the primary and one for the secondary barrier calculation. The interface of the primary barrier is divided into four tabs: (a) primary radiation, (b) patient scattered and leakage radiation, (c) IMRT techniques and (d) the shielding cost calculations. The interface of the secondary barrier includes three tabs: (a) patient scattered and leakage radiation, (b) IMRT techniques and (c) the shielding cost calculations. Each tab consists of two sections: one for input and one for output of the necessary data. The RISC is based on the methods and formulae of the NCRP 151 and calculates the primary and secondary barrier thickness for ordinary concrete with a density of 2.35 g/cm3 and the cost for a radiotherapy room with a linear accelerator that performs conventional or IMRT techniques. Calculations can be performed for photon energies of 4, 6, 10, 15, 18, 20, 25 and 30 MV of a dual-energy linear accelerator, while instantaneous dose rate (IDR) calculations are also performed. The RISC has been validated using all comparative examples of NCRP 151 and the calculations from shielding reports of the Varian IX linear accelerator at Methodist Hospital of Willowbrook and Elekta Infinity at the University Hospital of Patras. The RISC is accompanied by two text files: (a) "Terminology," extensively describing all parameters, and (b) "User's Manual," providing useful instructions to the user. The RISC is user-friendly, simple, fast and precise, providing accurate shielding calculations and quickly and easily reproducing different shielding scenarios for a radiotherapy room with a linear accelerator. Additionally, it could be used during the educational process of shielding calculations by graduate students or trainee medical physicists. As a future work, the RISC will be updated with new features such as skyshine radiation, door shielding, and other types of machines and shielding materials.


Assuntos
Proteção Radiológica , Design de Software , Proteção Radiológica/métodos , Aceleradores de Partículas , Radioterapia/instrumentação , Radioterapia/métodos , Fótons
3.
Arq. ciências saúde UNIPAR ; 26(3): 927-948, set-dez. 2022.
Artigo em Português | LILACS | ID: biblio-1399509

RESUMO

Cuidados paliativos são um conjunto de procedimentos ofertados ao paciente por uma equipe multidisciplinar com objetivo de garantir bem-estar, autonomia,conforto e alívio de sintomas decorrentes de doença ou tratamento quando a cura é impossibilitada. O câncer representa uma das doenças que possuem chances de evoluir o paciente ao estágio terminal, momento em que cuidados paliativos são indicados e necessários. Dentro da equipe responsável, o cirurgião-dentista atua na prevenção, diagnóstico e tratamento de lesões expressas no sistema estomatognático que se manifestam estimuladas pelo câncer ou pelos tratamentos utilizados. O objetivo desta pesquisa é destacar a função do odontólogo dentro da equipe multidisciplinar paliativista para pacientes oncológicos. Trata-se de uma revisão bibliográfica sistemáticada literatura. Foram feitas buscas nas plataformas Biblioteca Virtual em Saúde (BVS) e Scientific Electronic Library Online (SciELO) e após aplicação dos critérios de inclusão e exclusão foram selecionados 14 artigos. A literatura evidencia que alterações orais estão relacionadas com o curso da neoplasia ou seu tratamento; as lesões mais descritas foram: mucosite, xerostomia, candidíase, cárie, periodontite e osteorradionecrose. Isso faz com que o paciente sofra limitações em realizar atividades básicas, alterando negativamente a sua qualidade de vida. A complexidade da manifestação oral pode interromper o tratamento antineoplásico. As medidas de enfrentamento mais empregadas para a saúde bucal do paciente oncológico são a laserterapia, bochechos com clorexidina 0,12%, instrução de higiene oral, uso de anti-inflamatórios, analgésicos e antifúngicos. A atuação do odontólogo na equipe multidisciplinar oncológica paliativista é indispensável para o controle das manifestações orais.


Palliative care comprises a set of procedures offered by a multidisciplinary team to patients who cannot be cured, aiming to restore and ensure well-being, autonomy, independence, comfort and relief from symptoms resulting from illness or treatments. Cancer commonly leads the patient to the terminal stage, and at this stage palliative care is indicated and necessary. Composing the multidisciplinary team, the dentist works in the prevention, diagnosis and treatment of injuries that arise in the stomatognathic system, which manifest themselves due to cancer or its treatments. The objective of this research was to highlight the work of the dentist in the multidisciplinary team of palliative care for cancer patients. This is a systematic bibliographic review of the literature, with an integrative character. Study searches were performed in the Virtual Health Library (VHL) and Scientific Electronic Library Online (SciELO). After applying the inclusion and exclusion criteria, 14 articles were selected. Results showed that oral alterations are completely related to the development of the neoplasm or its treatment; the most described lesions were: mucositis, xerostomia, candidiasis, osteoradionecrosis, radiation caries and periodontitis. These injuries make the patient suffer limitations to perform basic activities, such as eating or communicating, negatively altering their quality of life. The complexity of the oral manifestation can determine the interruption of the anticancer treatment. The most used coping measures for the oral healthof cancer patients are: low- potency laser therapy, mouthwash with 0.12% chlorhexidine, instructionin oral hygiene and use of anti-inflammatory, analgesic and antifungal drugs. The role of dentists in the multidisciplinary palliative oncology team is essential for the control of oral lesions.


Los cuidados paliativos son un conjunto de procedimientos ofrecidos al paciente por un equipo multidisciplinar con el objetivo de garantizar el bienestar, la autonomía, el confort y el alivio de los síntomas derivados de la enfermedad o del tratamiento cuando la curación es imposible. El cáncer representa una de las enfermedades que tienen posibilidades de evolucionar al paciente hasta la fase terminal, momento en el que los cuidados paliativos son indicados y necesarios. Dentro del equipo responsable, el cirujano dentista actúa en la prevención, diagnóstico y tratamiento de las lesiones expresadas en el sistema estomatognático que se manifiestan estimuladas por el cáncer o por los tratamientos utilizados. El objetivo de esta investigación es destacar la función del odontólogo dentro del equipo paliativo multidisciplinar para pacientes oncológicos. Se trata de una revisión bibliográfica sistemática. Se realizaron búsquedas en las plataformas Virtual Health Library (BVS) y Scientific Electronic Library Online (SciELO) y tras aplicar los criterios de inclusión y exclusión, se seleccionaron 14 artículos. La literatura muestra que las alteraciones orales están relacionadas con el curso del cáncer o su tratamiento; las lesiones más comúnmente descritas fueron: mucositis, xerostomía, candidiasis, caries, periodontitis y osteorradionecrosis. Esto hace que el paciente sufra limitaciones para realizar actividades básicas, alterando negativamente su calidad de vida. La complejidad de la manifestación oral puede interrumpir el tratamiento antineoplásico. Las medidas de afrontamiento más utilizadas para la salud bucodental de los pacientes con cáncer son la terapia láser, los enjuagues bucales con clorhexidina al 0,12%, las instrucciones de higiene bucodental y el uso de fármacos antiinflamatorios, analgésicos y antifúngicos. La actuación del odontólogo en el equipo multidisciplinar de oncología paliativa es fundamental para el control de las manifestaciones orales.


Assuntos
Cuidados Paliativos , Odontólogos , Oncologia/instrumentação , Equipe de Assistência ao Paciente/organização & administração , Radioterapia/instrumentação , Estomatite/complicações , Estomatite/diagnóstico , Sistema Estomatognático , Neoplasias Bucais/diagnóstico , Neoplasias Bucais/tratamento farmacológico , Neoplasias Bucais/radioterapia , Medicina Bucal/instrumentação , Tratamento Farmacológico/instrumentação
4.
Sci Rep ; 12(1): 14, 2022 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-34996956

RESUMO

The majority of local recurrences, after conservative surgery of breast cancer, occurs in the same anatomical area where the tumour was originally located. For the treatment of ductal carcinoma in situ (DCIS), a new medical device, named BAT-90, (BetaGlue Technologies SpA) has been proposed. BAT-90 is based on the administration of 90Y ß-emitting microspheres, embedded in a bio-compatible matrix. In this work, the Geant4 simulation toolkit is used to simulate BAT-90 as a homogenous cylindrical 90Y layer placed in the middle of a bulk material. The activity needed to deliver a 20 Gy isodose at a given distance z from the BAT-90 layer is calculated for different device thicknesses, tumour bed sizes and for water and adipose bulk materials. A radiobiological analysis has been performed using both the Poisson and logistic Tumour Control Probability (TCP) models. A range of radiobiological parameters (α and ß), target sizes, and densities of tumour cells were considered. Increasing α values, TCP increases too, while, for a fixed α value, TCP decreases as a function of clonogenic cell density. The models predict very solid results in case of limited tumour burden while the activity/dose ratio could be further optimized in case of larger tumour beds.


Assuntos
Neoplasias da Mama/radioterapia , Carcinoma Ductal de Mama/radioterapia , Carcinoma Intraductal não Infiltrante/radioterapia , Radioterapia/métodos , Simulação por Computador , Feminino , Humanos , Modelos Logísticos , Radioterapia/instrumentação , Dosagem Radioterapêutica , Carga Tumoral
5.
Rio de Janeiro; s.n; 2022. 171 f p. tab, fig.
Tese em Português | LILACS | ID: biblio-1399438

RESUMO

Esta tese teve como objetivo estimar a necessidade de radioterapia no Brasil a partir de dados epidemiológicos locais. O estudo foi desenvolvido em duas etapas que consistiram na estimativa de casos incidentes e, posteriormente, na classificação dos casos registrados nos Registros Hospitalares de Câncer (RHC) para integrar as árvores de decisão para o emprego do tratamento radioterápico conforme evidências e diretrizes clínicas de tratamento. As estimativas de casos incidentes em 2018 foram calculadas a partir de dados de Registros de Câncer de Base Populacional (RCBP) selecionados de acordo com critérios internacionais de qualidade e de dados corrigidos para causas mal definidas e não específicas na causa básica dos óbitos registrados no Sistema de Informação de Mortalidade (SIM) no período de 2007 a 2016. Foram calculadas razões de incidência/mortalidade (I/M) anuais para cada topografia, estratificadas por sexo e faixa etária nos RCBP selecionados. As razões I/M para 2018 foram estimadas para as regiões brasileiras a partir de modelos multiníveis de Poisson a partir de uma abordagem longitudinal com efeito aleatório no RCBP. As razões estimadas foram aplicadas ao número de óbitos ocorridos em 2018 por tipo de câncer, também corrigido para causas mal definidas e não específicas na causa básica, registrados no SIM. As distribuições dos dados por estadiamento obtidas a partir do RHC foram combinadas às frequências relativas por tipo de câncer incidente e aos dados das árvores de decisão do projeto Collaboration for Cancer Outcomes Research and Evaluation (CCORE) para uso da radioterapia. As estimativas de necessidade foram calculadas por tipo de câncer e para o conjunto das neoplasias, exceto pele não melanoma. Foram realizadas análises de sensibilidade para avaliar a relevância dos dados locais na estimativa de necessidade. O número necessário de equipamentos de radioterapia para atender os casos que se beneficiariam do tratamento em algum momento no curso da doença foi calculado e a análise da cobertura da oferta foi realizada. Para o Brasil, em 2018, foram estimados 506.462 casos novos de câncer, exceto pele não melanoma. Diferenças regionais nas razões I/M e no padrão de casos incidentes foram identificadas, podendo estar relacionadas a fatores socioeconômicos. Foi estimado que 53,55% dos casos novos no Brasil teriam necessidade de tratamento radioterápico. A maior necessidade de radioterapia foi identificada para o Norte: 55,32%, com um peso expressivo do câncer do colo do útero, tanto pela incidência como pelo número de casos em estágios avançados, para os quais a radioterapia é considerada tratamento de escolha. Para atender aos casos com necessidade de radioterapia no Brasil, foram estimados 497 equipamentos de radioterapia externa, sendo o déficit estimado em 114 para 2018 no país. Os maiores déficits foram observados para o Norte e para a rede assistencial do SUS. Em conclusão, o emprego de parâmetros internacionais não se mostrou adequado para a realidade brasileira. O planejamento de recursos para a assistência oncológica no Brasil demanda estimativas confiáveis baseadas nas necessidades locais para que as inequidades não sejam ainda mais agravadas.


This thesis aimed to estimate the need for radiotherapy in Brazil based on local epidemiological data. The study was developed in two stages which consisted of estimating incident cases and, later, classifying the cases registered in the Hospital Cancer Registries (RHC) to integrate decision trees for the use of radiotherapy according to evidence and clinical treatment guidelines. The estimates of incident cases in 2018 were calculated based on data from Population-Based Cancer Registries (RCBP) selected according to international quality criteria and from data corrected for ill-defined and non-specific causes in the underlying cause of deaths recorded in the System of Mortality Information (SIM) from 2007 to 2016. Annual incidence/mortality ratios (I/M) were calculated for each topography, stratified by sex and age group in the selected RCBP. The I/M ratios for 2018 were estimated for Brazilian regions using multilevel Poisson models from a longitudinal approach with random effect on the RCBP. The estimated reasons were applied to the number of deaths that occurred in 2018 by type of cancer, also corrected for ill-defined and non-specific causes in the underlying cause, recorded in the SIM. The staging data distributions obtained from the RHC were combined with the relative frequencies by type of incident cancer and data from the Collaboration for Cancer Outcomes Research and Evaluation (CCORE) project decision trees for radiotherapy use. Optimal utilization rates were estimated by type of cancer and for the set of tumors, except for non-melanoma skin. Sensitivity analyzes were performed to assess the relevance of local data in estimating the need. The number of radiotherapy equipment needed to attend to cases that would benefit from treatment at some point in the course of the disease was calculated and the analysis of the offer coverage was performed. For Brazil, in 2018, 506,462 new cases of cancer were estimated, except for non-melanoma skin. Regional differences in I/M ratios and in the pattern of incident cases were identified, which may be related to socioeconomic factors. It was estimated that 53.55% of new cases in Brazil would need radiotherapy. The greatest need for radiotherapy was identified for the North: 55.32%, with an expressive weight of cervical cancer, both in terms of incidence and the number of cases in advanced stages, for which radiotherapy is considered the treatment of choice. To meet the need for radiotherapy in Brazil, 497 external radiotherapy equipment were estimated, with an estimated deficit of 114 for 2018 in the country. The greatest deficits were observed for the North and for the SUS care network. In conclusion, the use of international parameters was not adequate for the Brazilian reality. The planning of resources for cancer care in Brazil requires reliable estimates based on local needs so that inequities are not further aggravated.


Assuntos
Humanos , Radioterapia/estatística & dados numéricos , Neoplasias/radioterapia , Neoplasias/epidemiologia , Radioterapia/instrumentação , Sistema Único de Saúde , Brasil , Incidência , Instituições Privadas de Saúde
6.
Nat Commun ; 12(1): 7149, 2021 12 09.
Artigo em Inglês | MEDLINE | ID: mdl-34887404

RESUMO

Radiotherapy is an important therapeutic strategy for cancer treatment through direct damage to cancer cells and augmentation of antitumor immune responses. However, the efficacy of radiotherapy is limited by hypoxia-mediated radioresistance and immunosuppression in tumor microenvironment. Here, we construct a stabilized theranostic nanoprobe based on quantum dots emitting in the near-infrared IIb (NIR-IIb, 1,500-1,700 nm) window modified by catalase, arginine-glycine-aspartate peptides and poly(ethylene glycol). We demonstrate that the nanoprobes effectively aggregate in the tumor site to locate the tumor region, thereby realizing precision radiotherapy with few side-effects. In addition, nanoprobes relieve intratumoral hypoxia and reduce the tumor infiltration of immunosuppressive cells. Moreover, the nanoprobes promote the immunogenic cell death of cancer cells to trigger the activation of dendritic cells and enhance T cell-mediated antitumor immunity to inhibit tumor metastasis. Collectively, the nanoprobe-mediated immunogenic radiotherapy can boost the abscopal effect to inhibit tumor metastasis and prolong survival.


Assuntos
Nanopartículas/química , Neoplasias/radioterapia , Neoplasias/terapia , Nanomedicina Teranóstica/métodos , Animais , Linhagem Celular Tumoral , Terapia Combinada , Células Dendríticas/imunologia , Células Dendríticas/efeitos da radiação , Feminino , Humanos , Imunoterapia , Raios Infravermelhos , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Neoplasias/imunologia , Neoplasias/mortalidade , Pontos Quânticos/química , Radioterapia/instrumentação , Radioterapia/métodos , Linfócitos T/imunologia , Linfócitos T/efeitos da radiação , Nanomedicina Teranóstica/instrumentação , Microambiente Tumoral/efeitos da radiação
7.
Sci Rep ; 11(1): 20409, 2021 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-34650081

RESUMO

This study aimed to develop a poly-ε-caprolactone (PCL) material that has a low melting point while maintaining the deformation ability. The new PCL (abbreviated as 4b45/2b20) was fabricated by mixing two types of PCL with different molecular weights, numbers of branches, and physical properties. To investigate the melting point, crystallization temperature, elastic modulus, and elongation at break for 4b45/2b20 and three commercially available masks, differential scanning calorimetry and tensile tests were performed. The melting point of 4b45/2b20 was 46.0 °C, and that of the commercially available masks was approximately 56.0 °C (55.7 °C-56.5 °C). The elastic modulus at 60 °C of 4b45/2b20 was significantly lower than the commercially available masks (1.1 ± 0.3 MPa and 46.3 ± 5.4 MPa, p = 0.0357). In addition, the elongation at break of 4b45/2b20 were significantly larger than the commercially available masks (275.2 ± 25.0% and 216.0 ± 15.2%, p = 0.0347). The crystallization temperature of 4b45/2b20 (22.1 °C) was clinically acceptable and no significant difference was found in the elastic modulus at 23 °C (253.7 ± 24.3 MPa and 282.0 ± 44.3 MPa, p = 0.4). As a shape memory-based thermoset material, 4b45/2b20 has a low melting point and large deformation ability. In addition, the crystallization temperature and strength are within the clinically acceptable standards. Because masks made using the new PCL material are formed with less pressure on the face than commercially available masks, it is a promising material for making a radiotherapy mask that can reduce the burden on patients.


Assuntos
Caproatos , Lactonas , Máscaras , Poliésteres , Radioterapia/instrumentação , Caproatos/química , Cristalização , Humanos , Lactonas/química , Poliésteres/química , Resistência à Tração , Temperatura de Transição
8.
J Synchrotron Radiat ; 28(Pt 5): 1444-1454, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34475292

RESUMO

Spatially fractionated ultra-high-dose-rate beams used during microbeam radiation therapy (MRT) have been shown to increase the differential response between normal and tumour tissue. Quality assurance of MRT requires a dosimeter that possesses tissue equivalence, high radiation tolerance and spatial resolution. This is currently an unsolved challenge. This work explored the use of a 500 nm thick organic semiconductor for MRT dosimetry on the Imaging and Medical Beamline at the Australian Synchrotron. Three beam filters were used to irradiate the device with peak energies of 48, 76 and 88 keV with respective dose rates of 3668, 500 and 209 Gy s-1. The response of the device stabilized to 30% efficiency after an irradiation dose of 30 kGy, with a 0.5% variation at doses of 35 kGy and higher. The calibration factor after pre-irradiation was determined to be 1.02 ±â€…0.005 µGy per count across all three X-ray energy spectra, demonstrating the unique advantage of using tissue-equivalent materials for dosimetry. The percentage depth dose curve was within ±5% of the PTW microDiamond detector. The broad beam was fractionated into 50 microbeams (50 µm FHWM and 400 µm centre-to-centre distance). For each beam filter, the FWHMs of all 50 microbeams were measured to be 51 ±â€…1.4, 53 ±â€…1.4 and 69 ±â€…1.9 µm, for the highest to lowest dose rate, respectively. The variation in response suggested the photodetector possessed dose-rate dependence. However, its ability to reconstruct the microbeam profile was affected by the presence of additional dose peaks adjacent to the one generated by the X-ray microbeam. Geant4 simulations proved that the additional peaks were due to optical photons generated in the barrier film coupled to the sensitive volume. The simulations also confirmed that the amplitude of the additional peak in comparison with the microbeam decreased for spectra with lower peak energies, as observed in the experimental data. The material packaging can be optimized during fabrication by solution processing onto a flexible substrate with a non-fluorescent barrier film. With these improvements, organic photodetectors show promising prospects as a cost-effective high spatial resolution tissue-equivalent flexible dosimeter for synchrotron radiation fields.


Assuntos
Radioterapia/instrumentação , Semicondutores , Fracionamento da Dose de Radiação , Desenho de Equipamento , Dosímetros de Radiação , Dosagem Radioterapêutica , Síncrotrons , Raios X
9.
Technol Cancer Res Treat ; 20: 15330338211043037, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34554027

RESUMO

Background: This study aimed to analyze the difference of setup reproducibility between Vacuum-lock bag and Thermoplastic mask in the radiotherapy for breast cancer. Methods: A total of 100 invasive breast carcinoma patients were collected, among whom 50 patients were immobilized with Vacuum-lock bag (VB group), and the other 50 patients were immobilized with Thermoplastic mask (TM group). Set up reproducibility in different axes and comfort levels between two groups at three treatment progress points during the radiation therapy were collected and analyzed. Results: The linear regression model showed that fixed device was an independent factor of radiotherapy setup error (SE). Further subgroup analysis based on different axes showed that the SE caused by the fixed device was obvious in all directions. The comfort level in the VB group was significantly larger than that in the TM group at the beginning of treatment, reduced as the treatment progress going on, and finally disappeared within three weeks. Conclusions: Thermoplastic mask could significantly reduce positioning errors in the radiotherapy of breast cancer. Although more discomfort was found in the TM group, it could be eliminated as the treatment progresses.


Assuntos
Neoplasias da Mama/radioterapia , Carcinoma/radioterapia , Imobilização/instrumentação , Planejamento da Radioterapia Assistida por Computador , Erros de Configuração em Radioterapia , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Conforto do Paciente , Radioterapia/instrumentação , Reprodutibilidade dos Testes
10.
Sci Rep ; 11(1): 17104, 2021 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-34429440

RESUMO

Recent studies indicate better efficacy and healthy tissue sparing with high dose-rate FLASH radiotherapy (FLASH-RT) cancer treatment. This technique delivers a prompt high radiation dose rather than fractional doses over time. While some suggest thresholds of > 40 Gy s-1 with a maximal effect at > 100 Gy s-1, accumulated evidence shows that instantaneous dose-rate and irradiation time are critical. Mechanisms are still debated, but toxicity is minimized while inducing apoptosis in malignant tissue. Delivery technologies to date show that a capability gap exists with clinic scale, broad area, deep penetrating, high dose rate systems. Based on these trends, if FLASH-RT is adopted, it may become a dominant approach except in the least technologically advanced countries. The linear induction accelerator (LIA) developed for high instantaneous and high average dose-rate, species independent charged particle acceleration, has yet to be considered for this application. We review the status of LIA technology, explore the physics of bremsstrahlung-converter-target interactions and our work on stabilizing the electron beam. While the gradient of the LIA is low, we present our preliminary work to improve the gradient by an order of magnitude, presenting a point design for a multibeam FLASH-RT system using a single accelerator for application to conformal FLASH-RT.


Assuntos
Aceleradores de Partículas/normas , Radioterapia/métodos , Elétrons/uso terapêutico , Humanos , Radioterapia/efeitos adversos , Radioterapia/instrumentação , Dosagem Radioterapêutica
11.
Radiat Oncol ; 16(1): 75, 2021 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-33865401

RESUMO

BACKGROUND: Despite modern treatment techniques, radiotherapy (RT) in patients with head and neck cancer (HNC) may be associated with high rates of acute and late treatment-related toxicity. The most effective approach to reduce sequelae after RT is to avoid as best as possible healthy tissues and organs at risk from the radiation target volume. Even small geometric changes can lead to a significant dose reduction in normal tissue and better treatment tolerability. The major objective of the current study is to investigate 3D printed, tooth-borne tissue retraction devices (TRDs) compared to conventional dental splints for head and neck RT. METHODS: In the current two-arm randomized controlled phase II trial, a maximum of 34 patients with HNC will be enrolled. Patients will receive either TRDs or conventional dental splints (randomization ratio 1:1) for the RT. The definition of the target volume, modality, total dose, fractionation, and imaging guidance is not study-specific. The primary endpoint of the study is the rate of acute radiation-induced oral mucositis after RT. The quality of life, local control and overall survival 12 months after RT are the secondary endpoints. Also, patient-reported outcomes and dental status, as well as RT plan comparisons and robustness analyzes, will be assessed as exploratory endpoints. Finally, mesenchymal stem cells, derived from the patients' gingiva, will be tested in vitro for regenerative and radioprotective properties. DISCUSSION: The preliminary clinical application of TRD showed a high potential for reducing acute and late toxicity of RT in patients with HNC. The current randomized study is the first to prospectively investigate the clinical tolerability and efficacy of TRDs for radiation treatment of head and neck tumors. TRIAL REGISTRATION: ClinicalTrials.gov; NCT04454697; July 1st 2020; https://clinicaltrials.gov/ct2/show/record/NCT04454697 .


Assuntos
Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Impressão Tridimensional , Radioterapia/instrumentação , Neoplasias das Glândulas Salivares/radioterapia , Dente/anatomia & histologia , Adolescente , Adulto , Idoso , Meios de Contraste , Fracionamento da Dose de Radiação , Feminino , Gengiva/efeitos da radiação , Humanos , Estimativa de Kaplan-Meier , Masculino , Células-Tronco Mesenquimais/efeitos da radiação , Pessoa de Meia-Idade , Mucosite/etiologia , Qualidade de Vida , Lesões por Radiação , Radioterapia (Especialidade) , Risco , Resultado do Tratamento , Xerostomia/etiologia , Adulto Jovem
13.
Rev Sci Instrum ; 92(2): 024103, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33648097

RESUMO

A compact X-band linear accelerator (LINAC) system equipped with a small and lightweight magnetron was constructed to develop a high-precision image-guided radiotherapy system. The developed LINAC system was installed in an O-ring gantry where cone-beam computed tomography (CBCT) was embedded. When the O-arm gantry is rotated, an x-ray beam is stably generated, which resulted from the stable transmission of radio frequency power into the X-band LINAC system. Quality assurance (QA) tests, including mechanical and dosimetry checks, were carried out to ensure safety and operation performance according to the American Association of Physicists in Medicine's TG-51, 142, an international standard protocol established by accredited institutions. In addition, delivery QA of the radiotherapy planning system was conducted to verify intensity-modulated radiotherapy techniques. Therefore, it was demonstrated that the developed X-band LINAC system mounted on the O-arm gantry proved to be valid and reliable for potential use in CBCT image-guided radiation therapy.


Assuntos
Aceleradores de Partículas/instrumentação , Radioterapia/instrumentação , Rotação , Desenho de Equipamento
14.
Int J Radiat Biol ; 97(5): 642-656, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33617395

RESUMO

PURPOSE: γH2AX biodosimetry has been proposed as an alternative dosimetry method for microbeam radiation therapy (MRT) because conventional dosimeters, such as ionization chambers, lack the spatial resolution required to accurately measure the MRT valley dose. Here we investigated whether γH2AX biodosimetry should be used to measure the biological valley dose of MRT-irradiated mammalian cells. MATERIALS AND METHODS: We irradiated human skin fibroblasts and mouse skin flaps with synchrotron MRT and broad beam (BB) radiation. BB doses of 1-5 Gy were used to generate a calibration curve in order to estimate the biological MRT valley dose using the γH2AX assay. RESULTS: Our key finding was that MRT induced a non-linear dose response compared to BB, where doses 2-3 times greater showed the same level of DNA DSB damage in the valley in cell and tissue studies. This indicates that γH2AX may not be an appropriate biodosimeter to estimate the biological valley doses of MRT-irradiated samples. We also established foci yields of 5.9 ± 0.04 and 27.4 ± 2.5  foci/cell/Gy in mouse skin tissue and human fibroblasts respectively, induced by BB. Using Monte Carlo simulations, a linear dose response was seen in cell and tissue studies and produced predicted peak-to-valley dose ratios (PVDRs) of ∼30 and ∼107 for human fibroblasts and mouse skin tissue respectively. CONCLUSIONS: Our report highlights novel MRT radiobiology, attempts to explain why γH2AX may not be an appropriate biodosimeter and suggests further studies aimed at revealing the biological and cellular communication mechanisms that drive the normal tissue sparing effect, which is characteristic of MRT.


Assuntos
Quebras de DNA de Cadeia Dupla/efeitos da radiação , Histonas/metabolismo , Radioterapia , Animais , Biomarcadores/metabolismo , Humanos , Camundongos , Radiometria , Radioterapia/instrumentação , Síncrotrons
15.
Vet Radiol Ultrasound ; 62(4): 507-511, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33567122

RESUMO

Bolus materials are commonly used for both human and veterinary radiation therapy (RT). Commercially available bolus materials often leave an air gap between the bolus and the skin which can lead to underdosing of the tumor. This prospective exploratory study evaluated the 6 MV X-ray and electron beam (6, 9, and 12 MeV) attenuating properties for two alternative bolus materials: McKesson lubricating jelly® (MLJ) and Aquasonic 100 Ultrasound gel® (AUG). The results comparing MLJ and water for 12 MeV and 9 MeV electron beams showed <3% difference, however, no other significant differences in radiation dose between water and MLJ nor AUG were seen. Findings demonstrated that both AUG and MLJ have radiation dose attenuating properties similar to water and supported use of these materials as alternative bolus materials for veterinary radiation therapy applications.


Assuntos
Lubrificantes , Imagens de Fantasmas , Radioterapia/instrumentação , Ondas Ultrassônicas , Animais , Elétrons , Géis , Radioterapia/veterinária , Dosagem Radioterapêutica/veterinária
17.
Anticancer Res ; 41(1): 503-508, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33419849

RESUMO

BACKGROUND/AIM: We aimed to investigate the dosimetric effects of a spacer placed between the pancreas and surrounding gastrointestinal structures in intensity-modulated radiation therapy (IMRT) planning to provide more effective radiation therapy for locally advanced pancreatic cancer (LAPC). PATIENTS AND METHODS: Treatment planning was performed for six patients with LAPC based on computed tomography images without spacers and with 5-mm or 10-mm spacers virtually inserted under the supervision of a hepatobiliary pancreatic surgeon. The prescription dose was 63 Gy in 28 fractions. RESULTS: With the exception of one case of pancreatic head cancer, planning target volume receiving ≥95% of the prescribed dose (PTV V95) was achieved by 90% or more by inserting a spacer, and by 95% or more in all 3 cases of pancreatic body and tail cancer by inserting a 10-mm spacer. CONCLUSION: IMRT with appropriate spacer placement may help provide high-dose treatment for LAPC and improve associated patient outcomes.


Assuntos
Tratamentos com Preservação do Órgão/instrumentação , Neoplasias Pancreáticas/radioterapia , Planejamento da Radioterapia Assistida por Computador , Radioterapia , Feminino , Humanos , Masculino , Metástase Neoplásica , Estadiamento de Neoplasias , Tratamentos com Preservação do Órgão/métodos , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/mortalidade , Radioterapia/instrumentação , Radioterapia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
18.
Strahlenther Onkol ; 197(2): 97-115, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32444903

RESUMO

PURPOSE: To determine whether rectal displacement devices (RDDs) have a prostate-stabilizing effect during prostate external beam radiotherapy (EBRT). METHODS: A systematic literature search using the PubMed database from January 1, 2000 to December 30th, 2019 was conducted. The effect of RDDs on inter- and intra-fractional prostate displacements was extracted. RESULTS: From 356 articles identified via the PubMed database and hand search, 21 articles were included in the systematic review. There was no randomized study. Twelve studies evaluated the role of the endorectal balloon (ERB) in managing prostate motion. Four studies reported the effect of hydrogel spacer on prostate motion. Four studies examined the effect of the rectal retractor (RR) on intra-fractional prostate motion, and only one study assessed the impact of ProSpare (Nottinghamshire, UK) in reducing prostate motion. CONCLUSION: Using an ERB significantly reduces intra-fractional prostate motion. This prostate-stabilizing effect of the ERB can translate into reduced planning target volume (PTV) margins and additional rectal dose sparing. Even with an ERB in place, inter-fractional prostate displacements are seen. As a consequence, ERB application does not obviate daily verification; however, this is not a crucial topic because pretreatment imaging is always done nowadays. As compared with ERB, the hydrogel spacer significantly reduces rectal dose and toxicity without influencing prostate immobilization. The RR can increase prostate and rectal inter- and intra-fractional stability without a clear influence on the reduction of rectal toxicity. Finally, it is unclear whether ProSpare is a suitable device reducing prostate motion. Further study will be required to clarify whether the prostate-stabilizing effects of the ERB and RR can result in a safe reduction of PTV margins and further sparing of organs at risks, especially the rectum.


Assuntos
Próstata , Neoplasias da Próstata/radioterapia , Radioterapia/instrumentação , Reto , Desenho de Equipamento , Humanos , Masculino , Movimento (Física) , Próstata/efeitos da radiação , Reto/efeitos da radiação
19.
Radiol Med ; 126(4): 623-629, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33242206

RESUMO

BACKGROUND: Despite the pivotal role of radiotherapy in oncology, the provision of radiation treatments remains inadequate in many areas of the world. The present report is an assessment conducted among Radiation Oncology centers of Veneto region with the aim to collect information concerning radiotherapy assets and technological equipment availability. METHODS: Data concerning Veneto Radiation Oncology departments about radiotherapy activities, number of treatments, techniques used and radiotherapy machines available were collected. The reference time period was 2018. Reimbursement system databases and business intelligence systems were used. Extra-regional attraction and migration were evaluated. When available, data were compared to previous years. RESULTS: Veneto in 2018 was endowed with 1 megavolt unit for about 153,000 inhabitants. The number of megavolt machines per million inhabitants resulted to be 6.72. In 51% of radiotherapy treatments, intensity-modulated techniques were performed. Six percent of treatments were administered to extra-regional patients. CONCLUSION: Radiotherapy assets and equipment in Veneto seem to be appropriate to standard requests in terms of availability and technology.


Assuntos
Radioterapia (Especialidade)/estatística & dados numéricos , Radioterapia/estatística & dados numéricos , Equipamentos e Provisões/provisão & distribuição , Humanos , Itália , Radioterapia (Especialidade)/instrumentação , Radioterapia/instrumentação
20.
J Med Imaging Radiat Sci ; 51(4): 590-598, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32948475

RESUMO

BACKGROUND: Thermoplastic immobilization masks used during radiation therapy treatment have been shown to harbor several different types of bacteria. Recovered bacteria included Staphylococcus aureus, Enterococcus species, Gram-negative rods, coagulase-negative staphylococci, and several different Bacillus species. Two of the recovered Bacillus bacteria were examined for their ability to attach to and survive over time on patient head-only masks from four different manufacturers. B. halosaccharovorans was recovered from a treatment facility's water bath while B. cereus was recovered from a patient mask in the same facility. Bacillus bacteria were chosen for this study due to their capability to form dormant spores. METHODS: Inoculums containing either B. halosaccharovorans or B. cereus bacteria were seeded onto predesignated areas of each test mask. Masks were subsequently sampled at intervals of 1-h, 1 week, 2 weeks, 3 weeks, and 4 weeks. Recovered bacterial numbers at each sampling interval were determined using the direct plate count method. Spore stains were made of both bacterial isolates and number of detected spores were enumerated. RESULTS: B. halosaccharovorans attached to each mask type after a 1-h contact time at a number 3X greater than B. cereus. B. halosaccharovorans was also recovered at a number 8.5X greater than B. cereus after 4 weeks. Variation was seen in the attachment capability of each bacterium on tested mask types. Both bacilli were recovered from all 4 masks at each sampling interval including week 4. Examination of spore stains of each bacteria demonstrated nearly a 25:1 ratio of B. halosaccharovorans spores over B. cereus. DISCUSSION: The large variation seen between B. halosaccharovorans and B. cereus capability to attach to each of the four tested masks is revealing, especially when it is combined with determined spore numbers. It suggests that spores play a role in mediating their attachment to mask surfaces. Moreover, the recovery of both bacteria from stored masks after 4 weeks indicates a continued presence of dormant spores since growth-supportive nutrients are lacking. It also implies the potential for their transfer to a patient wearing a contaminated mask during a treatment session. CONCLUSION: The demonstrated ability of these two Bacillus bacteria to attach to and reside on patient masks presents a dilemma. Routine cleaning with approved disinfectants may not be sufficient to eliminate dormant spores on masks surfaces. This matter requires further investigation. For now, a small modification to the routine mask cleaning procedure before its application may help to reduce the possibility of spore transfer.


Assuntos
Bacillus cereus/crescimento & desenvolvimento , Bacillus cereus/isolamento & purificação , Bacillus/crescimento & desenvolvimento , Bacillus/isolamento & purificação , Máscaras/microbiologia , Radioterapia/instrumentação , Contagem de Colônia Microbiana , Imobilização/instrumentação